W1219 Temperature Controller Dual Display – 12Vdc

W1219 Temperature Controller Dual Display – 12Vdc

  • Name: W1219 Temperature Controller+
  • Model: XH-W1219
  • Control range: -50°C to 110°C
  • Control accuracy: 0.1°C
  • Measurement input: NTC10K waterproof sensor L=0.5M
  • High temperature alarm: -49°C to 110°C
  • Input voltage: DC 12V
  • Output type: relay output up to 10A
  • Return difference setting: 0.1°C to 30°C
  • Delayed start: 0-10 minutes
  • Temperature correction: -10°C to +10°C
  • Size: 60*43*16mm (length*width*height)
SKU: B10D18

Safe shopping

Your data is always protected

Sale_coupon_15

275.00EGP

In stock

In stock

12 People watching this product now!
  • In-Store Pickup

Everyday from 9 AM to 7 PM

  • ARAMEX Shipping

2-3 Days

Total fees when checkout

  • Return within 14 days

Payment Methods:

Description

W1219 Temperature Controller Dual Display – 12Vdc

  • Name: W1219 Temperature Controller
  • Model: XH-W1219
  • Control range: -50°C to 110°C
  • Control accuracy: 0.1°C
  • Measurement input: NTC10K waterproof sensor L=0.5M
  • High temperature alarm: -49°C to 110°C
  • Input voltage: DC 12V
  • Output type: relay output up to 10A
  • Return difference setting: 0.1°C to 30°C
  • Delayed start: 0-10 minutes
  • Temperature correction: -10°C to +10°C
  • Size: 60*43*16mm (length*width*height)
How to restore factory settings:
Under normal power, press and hold the + and – key for about three seconds to restore factory settings.
  1. PO temperature control mode: This value must be set when the thermostat is used for the first time. If it is used for heating, it must be set to H. If it is used for cooling, it should be set to C.
  2. P1 difference setting: Press the SET button for a long time to enter the internal settings, select the P1 setting, and then press the SET button again to set the hysteresis value. (The hysteresis is the difference needed when the thermostat reaches the set temperature and stops working again.)
  3. P2 temperature calibration: This function is used for temperature calibration. If there is a deviation between the detected temperature and the actual temperature, this function can be used to correct. The corrected value = measured value + correction value. (If you do not control the compressor or do not need delay function, skip this item directly)
  4. P4 high temperature alarm: Set the high temperature alarm value. When the real-time temperature exceeds this value, the screen will flash warning alarm.
Package includes:
  • 1x W1219 Dual Display Temperature Controller 12Vdc
  • 1 x NTC Sensor

Documents:

Related Products: